Skip to the calculator
DIVELUX More free sauna tools

Löyly Calculator

Löyly is the Finnish word for the steam that rises when water hits the stones. Enter the temperature and humidity of your sauna and see how much water is in the air, and how much more it takes to raise the humidity.

Units
The air now

Read both in the same spot, such as head height on the bench where you sit. Humidity only means something together with the temperature it was read at.

The room

Length times width times ceiling height. A room 6 ft by 5 ft with a 7 ft ceiling is 210 cu ft.

More humidity

Percentage points of relative humidity. 10 takes a room at 15% to 25%. Enter 0 to only look at the air as it is.

Water to raise the humidity

Enter the air and the room

The calculator needs JavaScript. The formulas it uses are written out below.

This is the least water it could take, not a recipe. The figure is the water that must become vapor and stay in the air. In a real sauna some steam leaves through the vents and the door, some soaks into the wood, and some water runs through the stones without boiling. Pour a little at a time, stand clear of the stones, and go by how the room feels.

How the numbers are worked out

This is textbook psychrometry, the physics of air and water vapor. Every formula and constant below is a published standard. None are ours.

  1. Saturation vapor pressure. The most water vapor air can hold depends only on temperature. The page takes it from the saturation equation of IAPWS-IF97, the international steam-table standard. It is valid from 0 °C (32 °F) up, which covers every sauna.
  2. Vapor pressure now. Relative humidity is the share of that maximum which is in use. Vapor pressure = saturation pressure × relative humidity.
  3. Dew point. The temperature at which that vapor pressure would be saturation. Any surface cooler than the dew point collects condensation. The page gets it from the inverse steam-table equation, so no approximation is added.
  4. Absolute humidity. Grams of water vapor in a cubic meter of air, from the ideal gas law with the gas constant of water vapor, 461.5 J/(kg·K).
  5. Water to raise the humidity. Room volume × the rise in absolute humidity. One gram of water is one milliliter.
  6. The ceiling above the boiling point. Vapor pressure cannot be higher than the pressure in the room, and a sauna is open to the outside air. At standard sea-level pressure, relative humidity can reach 100% only up to 212 °F (100 °C). Above that the most it can be is air pressure divided by saturation pressure: about 71% at 230 °F (110 °C). The page will not accept a reading above that limit.
Saturation vapor pressure: this page against the NIST steam tables.
TemperatureNISTThis pageMagnus formula
20 °C (68 °F)2.3393 kPa2.3392 kPa2.3334 kPa (−0.2%)
50 °C (122 °F)12.352 kPa12.351 kPa12.361 kPa (+0.1%)
80 °C (176 °F)47.414 kPa47.415 kPa48.040 kPa (+1.3%)
100 °C (212 °F)101.42 kPa101.42 kPa104.08 kPa (+2.6%)
110 °C (230 °F)143.38 kPa143.38 kPa148.24 kPa (+3.4%)

The Magnus formula is what most weather and dew point calculators use. Its usual coefficients were fitted for −40 to 50 °C, so it reads high in a hot sauna. That is why this page uses the steam-table equation instead.

The ideal gas law is also an approximation. Against the same NIST tables it reads about 0.9% low for saturated vapor at 80 °C and 1.6% low at 100 °C, and less than that at ordinary sauna humidity. Either error is small next to what vents and wood do in a real room.

Sources

What this page does not know. How fast your room changes its air, how dry the wood is, how hot the stones are, where your hygrometer hangs and how accurate it is. Sauna air is not evenly mixed: it is hotter and wetter near the ceiling right after a pour. The page assumes standard sea-level air pressure; at altitude the ceiling on humidity above the boiling point is lower. It does not give a "feels like" temperature. There is no agreed formula for one at sauna conditions, so we do not print one.

The code is open source under the MIT license, so you can read every line.